Designed for hygienic applications, the Rosemount 2090F Hygienic Pressure Transmitter is specifically engineered for the pharmaceutical and food and beverage industries. Built with industry standard process connections, this device connects to sanitary fittings without special mounting hardware. In addition, this hygienic pressure transmitter conforms to 3-A® Sanitary Standards, allowing you to meet tough process requirements.

– Product Datasheet  – Download
Accuracy ± 0.20 percent of calibrated span
Long term stability ± 0.10 percent of URL for one year
Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 300 psia (20,7 bar) Absolute
Measurement type Gage, Absolute
Transmitter output 4-20 mA HART
Process Wetted Material 316L SST
   
Approvals and certifications ATEX, IECEx, INMETRO, XP & DIP, EAC, Canada Explosion proof, Intrinsic Safety, Division 2
Enclosures rating NEMA® Type 4x, IP66, IP68, and IP69K when properly installed
Industry standards and commercial approvals 3-A Sanitary Standards, hazardous location
   
Measurement application software option  
ETO product option  
Certificates, tests, calibrations, and services Available