Low-footprint, drainable R-Series Coriolis flow meters provide accurate flow and density measurements. They are ideally suited for general purpose applications that typically require repeatable, reliable, low-maintenance measurements.
Accuracy and repeatability on liquids | |
Mass flow accuracy | Up to ±0.4% of rate |
Volume flow accuracy | Up to ±0.4% of rate |
Mass flow repeatability | Up to 0.2% of rate |
Volume flow repeatability | Up to 0.2% of rate |
Density accuracy | Up to ±3 kg/m³ |
Density repeatability | Up to 1.5 kg/m³ |
Temperature accuracy | ±1 °C ±0.5% of reading |
Temperature repeatability | 32.36 °F (0.200 °C) |
Accuracy and repeatability on gases | |
Mass flow accuracy | ±0.75% of rate |
Mass flow repeatability | 0.5% of rate |
Temperature accuracy | ±1 °C 0.5% of reading |
Temperature repeatability | 32.36 °F (0.200 °C) |
Line Size | 1/4″ (DN6) – 2″ (DN50) |
Pressure Range | Up to 1450 psig (100 barg) |
Temperature Range | -148 to 302°F (-100 to 150°C) |
Approvals and certifications | CSA, CSA C-US, ATEX, IECEx, NEPSI |
Ingress Protection | IP 66/67 for sensors and transmitters |
Industry standards | |
Industry standards and commercial approvals | NAMUR: NE132, NE131, PED, CRN, Dual Seal, ASME B31.3 Piping Code, SIL2 and SIL3 safety certifications |
Electronics (soft) | Expansive I/O options including mA, Frequency, Discrete, HART, Modbus, Ethernet/IP, PROFINET, FOUNDATION Fieldbus |
Materials of construction | 316L Stainless steel |
Flanges | ASME B16.5, EN 1092-1, JIS B2220, Hygienic tri-clamp, NAMUR NE 132, VCO, VCR |
Measurement application software option | |
ETO product option | |
Certificates, tests, calibrations, and services | Available |
Micro Motion R-Series